- Etapa de clarificare
- Depunerea ofertelor
- Licitație electronică
- Etapa de evaluare a ofertelor
- Contract
Echipament portabil de prelevare a datelor biometrice
Informaţia despre Autoritatea Contractantă
Denumirea
Codul fiscal/IDNO
Adresa
Web site
Persoana de contact
Nume Prenume
Telefonul de contact
Fax
Datele achiziției
Data publicării
Ultima modificare
MTender ID
Cod CPV
Tip de procedură
Criteriu de evaluare
Lista loturilor
Denumirea lotului : Echipament portabil de prelevare a datelor biometrice
Conform cerințelor tehnice din Anexa la Anunțul de participare
Statut
Valoarea estimată
ID
Pas minim
Termen de valabilitate al contractului
De la 30.04.2025 14:51:32 Până la 30.12.2025 15:51:32
Link-ul către licitație
Începutul licitației
De la 09.04.2025 15:00:00
Documentele procedurii de achiziție
Anexa la Anuntul de participare.docx
Documentaţie de atribuire
03.03.2025 15:54:17
Anexa la Anuntul de participare.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
Anexa nr. 24 - Contract model.docx
Documentaţie de atribuire
03.03.2025 15:54:17
Anexa nr. 24 - Contract model.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
Anexe la documentatia standard.docx
Documentaţie de atribuire
03.03.2025 15:54:17
Anexe la documentatia standard.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
Anunt de participare .signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
Annex no. 24 - Equipment mobile biometric.docx
Documentaţie de atribuire
03.03.2025 15:54:17
Annex no. 24 - Equipment mobile biometric.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
Annex to Procurement notice engl.docx
Documentaţie de atribuire
03.03.2025 15:54:17
Annex to procurement notice engl.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
Annexes to standard documentation engl.docx
Documentaţie de atribuire
03.03.2025 15:54:17
Annexes to standard documentation engl.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
ESPD - duae engl.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
Procurement notice engl.signed.pdf
Documentaţie de atribuire
03.03.2025 15:54:17
13.03.2025 10:40
Răspuns la clarificare: As per the technical requirements, the system must feature integrated lighting with dynamic ambient light intensity adjustment to ensure optimal biometric image capture in varying environmental conditions. In response to your question, we confirm that manual adjustment capabilities in addition to dynamic adjustment are acceptable, provided that: • The dynamic ambient light intensity adjustment remains the primary method of adaptation to changing lighting conditions. • The manual adjustment feature functions as a supplementary option without compromising compliance with ISO/IEC 19794-5:2011 for biometric image capture. • The proposed solution does not degrade the optimized LED non-flash illumination requirement specified in the tender. We appreciate your interest and encourage you to ensure full compliance with all listed specifications.
13.03.2025 10:45
Răspuns la clarificare: The HDMI port is intended primarily for video output, allowing connection to external monitors or display devices when needed. This can be useful for real-time visualization of biometric data capture, training purposes, or administrative reviews. However, its use is secondary to the USB interface, which serves as the primary method for data transfer and external device connectivity. Regarding USB specifications, the requirement explicitly states USB 3.0 to ensure high-speed data transfer and compatibility with modern peripherals. Additionally, USB-C connectivity is acceptable, provided it maintains full compliance with the required USB 3.0 data transfer rates and functionalities.
13.03.2025 11:09
Răspuns la clarificare: The requirement states that the distance range and height adjustments must be compliant with standard biometric image capture requirements to ensure optimal image quality and compliance with ICAO/ISO standards. In response to your question, we confirm that manual adjustments for camera settings, such as focus and zoom, are acceptable, provided that: • They serve as supplementary adjustments and do not replace or interfere with the system's ability to automatically adjust for biometric image capture. • The system remains fully compliant with ISO/IEC 19794-5 and ICAO standards regarding face image quality and processing. • The manual adjustment functions are user-friendly and do not compromise the efficiency of the biometric data collection process.
13.03.2025 11:21
Răspuns la clarificare: The requirement for "LCD color with encryption" is intended to ensure the secure capture and transmission of signature data, in compliance with industry-standard security protocols. Below are the expected encryption details: • Encryption type: symmetric encryption (e.g., AES) is preferred for real-time data security, but asymmetric encryption (e.g., RSA) may be acceptable depending on implementation. • Encryption standard: the minimum required standard is AES-256 for symmetric encryption or RSA-2048 for asymmetric encryption. • Encryption location: encryption should be performed directly on the signature pad before transmission to prevent data interception. • Data transmission security: encrypted signature data must be transmitted securely using TLS 1.2 or higher. • Key management: if the signature pad supports encryption key management, it must comply with ISO/IEC 27001 security standards for cryptographic key handling. If your proposed solution meets or exceeds these security requirements, it will be considered compliant with the tender specifications.
Depunerea ofertelor
Valoarea estimată fără TVA03.03.2025 15:54:17 - 13.03.2025 12:30:00
13.03.2025 12:30:00 - 08.04.2025 11:30:00